Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.124
Filtrar
1.
BMJ Case Rep ; 17(4)2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38569739

RESUMO

Osteoid osteoma is a benign osteoblastic tumour with a predilection for the lower extremity that rarely affects the forearm. It is commonly seen in adolescents and young adults, and is seldom diagnosed in the paediatric age group. We report a boy in his early childhood who presented with a swelling over the distal forearm, which was incidentally noted by the mother 3 months ago. Plain radiographs showed diffuse sclerosis of the dorsal cortex of the distal radius. CT scan showed a central lucent nidus in the intramedullary region and surrounding sclerosis in the radial metaphysis, confirming the diagnosis of osteoid osteoma. The patient was successfully treated by surgical en bloc resection of the nidus and was asymptomatic at 1-year follow-up. Non-specific symptoms at presentation make it a challenge to diagnose osteoid osteoma in children and it needs to be considered in the differential diagnosis when radiographs show lytic lesions in the bone.


Assuntos
Neoplasias Ósseas , Osteoma Osteoide , Masculino , Adulto Jovem , Adolescente , Humanos , Pré-Escolar , Criança , Osteoma Osteoide/diagnóstico por imagem , Osteoma Osteoide/cirurgia , Rádio (Anatomia)/diagnóstico por imagem , Rádio (Anatomia)/cirurgia , Rádio (Anatomia)/patologia , Esclerose/patologia , Neoplasias Ósseas/diagnóstico por imagem , Neoplasias Ósseas/cirurgia , Ulna
3.
J Int Med Res ; 52(3): 3000605241233418, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38548472

RESUMO

OBJECTIVES: Despite being an important research topic in oral biomaterials, few studies have demonstrated the differences between poly(d,l-lactide-co-glycolide)/hydroxyapatite (PLGA/HA) and poly(d,l-lactic acid)/hydroxyapatite (PDLLA/HA). In this study, PLGA/HA and PDLLA/HA scaffolds were prepared using three-dimensional (3D) printing technology and implanted into radius defects in rabbits to assess their effects on bone regeneration. METHODS: In this study, 6 mm × 4 mm bone defects were generated in the bilateral radii of rabbits. 3D-printed PLGA/HA and PDLLA/HA scaffolds were implanted into the defects. X-ray imaging, micro-computed tomography, and hematoxylin-eosin staining were performed to observe the degradation of the materials, the presence of new bone, and bone remodeling in the bone defect area. RESULTS: The PLGA/HA scaffolds displayed complete degradation at 20 weeks, whereas PDLLA/HA scaffolds exhibited incomplete degradation. Active osteoblasts were detected in both groups. The formation of new bone, bone marrow cavity reconstruction, and cortical bone remodeling were better in the PLGA/HA group than in the PDLLA/HA group. CONCLUSIONS: PLGA/HA scaffolds performed better than PDLLA/HA scaffolds in repairing bone defects, making the former scaffolds more suitable as bone substitutes at the same high molecular weight.


Assuntos
Ácido Poliglicólico , Rádio (Anatomia) , Animais , Coelhos , Copolímero de Ácido Poliláctico e Ácido Poliglicólico , Rádio (Anatomia)/diagnóstico por imagem , Rádio (Anatomia)/cirurgia , Ácido Láctico , Microtomografia por Raio-X , Durapatita , Impressão Tridimensional , Tecidos Suporte
4.
J Hand Surg Asian Pac Vol ; 29(2): 140-147, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38494166

RESUMO

Background: The long axis of the radius is a standard reference for measuring radiological parameters in distal radius fractures. However, in patients with severe comminution and anatomical variation with distal radius bowing, it is challenging to assess using the long axis of the radius. The long axis of the ulna can be used as an alternative reference. The aim of this study is to assess the reliability and level of agreement using the long axis of the ulna as an alternative reference in comparison to the long axis of the radius. Methods: Posteroanterior (PA) radiography of the wrist in patients with acute distal radius fractures was evaluated in two rounds by four observers. Radial height, radial inclination and ulnar variance were measured using radial and ulnar long axis as references. The intraobserver and interobserver reliability of the measurements with two reference axes was assessed using intraclass correlation coefficient (ICC). The level of agreement was determined using the Bland-Altman plot. Results: In total, 59 patients who underwent PA radiography of the wrist were included in this study. All parameters exhibited good agreement between the two methods, with a mean difference of nearly zero (radial height = -0.03 mm, radial inclination = -0.14° and ulnar variance = 0.03 mm). The limits of agreement in radial height (-2.87, 2.82 mm) and ulnar variance (-0.81, 0.87 mm) were narrow. However, for the radial inclination, it was wider (-6.21, 5.94°). Intraobserver reliability between the long axis of radius and ulna (ICC = 0.85-0.99 and 0.84-0.98, respectively) was good to excellent. The interobserver reliability of each parameter was excellent (ICC = 0.94-0.97). Conclusions: The ulnar long axis can be used as an alternative reference for measuring radial height, radial inclination and ulnar variance in PA radiography of the wrist in acute distal radius fracture, particularly if the radial long axis is distorted. Level of Evidence: Level III (Diagnostic).


Assuntos
Fraturas do Rádio , Fraturas do Punho , Humanos , Rádio (Anatomia)/diagnóstico por imagem , Fraturas do Rádio/diagnóstico por imagem , Reprodutibilidade dos Testes , Ulna/diagnóstico por imagem , Radiografia
5.
J Bone Miner Res ; 39(3): 271-286, 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38477754

RESUMO

Data on bone microarchitecture in osteogenesis imperfecta (OI) are scarce. The aim of this cross-sectional study was to assess bone microarchitecture and strength in a large cohort of adults with OI using high-resolution peripheral quantitative computed tomography (HR-pQCT) and to evaluate challenges of using HR-pQCT in this cohort. Second-generation HR-pQCT scans were obtained at the distal radius and tibia in 118 men and women with Sillence OI type I, III, or IV using an extremity-length-dependent scan protocol. In total, 102 radius and 105 tibia scans of sufficient quality could be obtained, of which 11 radius scans (11%) and 14 tibia scans (13%) had a deviated axial scan angle as compared with axial angle data of 13 young women. In the scans without a deviated axial angle and compared with normative HR-pQCT data, Z-scores at the radius for trabecular bone mineral density (BMD), number, and separation were -1.6 ± 1.3, -2.5 ± 1.4, and -2.7 (IQR: 2.7), respectively. They were -1.4 ± 1.5 and -1.1 ± 1.2 for stiffness and failure load and between ±1 for trabecular thickness and cortical bone parameters. Z-scores were significantly lower for total and trabecular BMD, stiffness, failure load, and cortical area and thickness at the tibia. Additionally, local microarchitectural inhomogeneities were observed, most pronounced being trabecular void volumes. In the scans with a deviated axial angle, the proportion of Z-scores <-4 or >4 was significantly higher for trabecular BMD and separation (radius) or most total and trabecular bone parameters (tibia). To conclude, especially trabecular bone microarchitecture and bone strength were impaired in adults with OI. HR-pQCT may be used without challenges in most adults with OI, but approximately 12% of the scans may have a deviated axial angle in OI due to bone deformities or scan positioning limitations. Furthermore, standard HR-pQCT parameters may not always be reliable due to microarchitectural inhomogeneities nor fully reflect all inhomogeneities.


OI is a rare condition with large clinical heterogeneity. One of the major characteristics associated with OI is the increased fracture risk due to defects in bone structure and material. Data on the defects in bone structure at the micrometer level (i.e. bone microarchitecture) are scarce. Bone microarchitecture can be assessed noninvasively using HR-pQCT, but its use in OI has not extensively been described. Yet, potential challenges may arise related to among others the occurrence of short extremities and skeletal deformities in OI. We assessed bone microarchitecture and strength in 118 adults with OI types I, III, or IV using HR-pQCT with an extremity-length-dependent scan protocol. Additionally, we evaluated potential challenges of using HR-pQCT in this cohort. Our results demonstrated that predominantly trabecular microarchitecture­especially trabecular number and separation­and overall bone strength were impaired in adults with OI as compared with normative data. Furthermore, we observed various microarchitectural inhomogeneities, most pronounced being trabecular void volumes. Regarding applicability, HR-pQCT could be used without challenges in most adults with OI. However, deviations in scan region may potentially influence HR-pQCT parameters, and standard HR-pQCT analyses may not always give accurate results due to microarchitectural inhomogeneities nor fully reflect all microarchitectural inhomogeneities.


Assuntos
Osteogênese Imperfeita , Adulto , Masculino , Humanos , Feminino , Osteogênese Imperfeita/diagnóstico por imagem , Estudos Transversais , Densidade Óssea , Osso e Ossos/diagnóstico por imagem , Tíbia/diagnóstico por imagem , Rádio (Anatomia)/diagnóstico por imagem , Extremidade Superior , Absorciometria de Fóton
6.
Ulus Travma Acil Cerrahi Derg ; 30(2): 135-141, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38305653

RESUMO

BACKGROUND: Although isolated distal radius and radial head fractures are common injuries, simultaneous ipsilateral fractures are uncommon. They can range from simple undisplaced fractures at either end to severely comminuted ipsilateral proximal and distal radial fractures. Few cases have been reported with concomitant comminuted distal radius and radial head fractures, and no treatment guidelines are available. Decisions are often based on personal recommendations. The purpose of our study is to increase awareness of this injury pattern and to discuss the mechanism of injury, treatment approach, and functional outcome. METHODS: Skeletally mature patients with comminuted simultaneous ipsilateral fractures of the distal and proximal radius from 2016 to 2021 were identified and studied retrospectively. Demographic information, mechanism of injury, treatment approach, and complication rate were analyzed. Radiographic assessment for inadequacy or loss of reduction and radiographic parameters of the distal radius, including radial inclination, radial length, and palmar inclination, was performed immediately postoperatively and at the final follow-up. Clinical outcomes were determined by calculating the Visual Analog Scale (VAS) score, measuring the range of motion in both joints, and using the Quick Disabilities of the Arm, Shoulder and Hand (QuickDASH) score at the final follow-up. RESULTS: A total of 11 patients met the inclusion criteria. All had ipsilateral Mason III radial head fractures and type C (according to the Arbeitsgemeinschaft für Osteosynthesefragen (AO) classification) intra-articular distal radius fracture. On-table radial head reconstruction and fixation with a proximal radius plate were used for radial head fractures, and osteosynthesis with an anatomic volar locking plate was used for distal radius fractures. The mean follow-up duration was 32 months (range 12-65 months). At the final follow-up, osseous union of both the radial head and distal radius was observed in all patients. The mean VAS score was 1.5 (range 0-7) at rest and 3.9 (range 0-9) with activities, while the mean QuickDASH score was 32 (range 12-65). No significant complications were recorded. CONCLUSION: Simultaneous comminuted fractures of the ipsilateral distal radius and radial head represent a distinct injury pattern, most likely resulting from high-energy trauma, such as falling from a height onto an outstretched hand. Greater emphasis should be placed on clinical examination and radiological imaging of the elbow in cases of wrist injuries and vice versa. Treatment involving on-table reconstruction of the radial head and open reduction and internal fixation with a volar plate can lead to good radiological and functional outcomes.


Assuntos
Fraturas Cominutivas , Fraturas da Cabeça e do Colo do Rádio , Fraturas do Rádio , Humanos , Rádio (Anatomia)/diagnóstico por imagem , Rádio (Anatomia)/cirurgia , Rádio (Anatomia)/lesões , Fraturas Cominutivas/diagnóstico por imagem , Fraturas Cominutivas/cirurgia , Estudos Retrospectivos , Fraturas do Rádio/diagnóstico por imagem , Fraturas do Rádio/cirurgia , Fixação Interna de Fraturas/métodos , Amplitude de Movimento Articular , Placas Ósseas , Resultado do Tratamento
7.
Osteoporos Int ; 35(5): 863-875, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38349471

RESUMO

Non-pharmacological therapies, such as whole-food interventions, are gaining interest as potential approaches to prevent and/or treat low bone mineral density (BMD) in postmenopausal women. Previously, prune consumption preserved two-dimensional BMD at the total hip. Here we demonstrate that prune consumption preserved three-dimensional BMD and estimated strength at the tibia. PURPOSE: Dietary consumption of prunes has favorable impacts on areal bone mineral density (aBMD); however, more research is necessary to understand the influence on volumetric BMD (vBMD), bone geometry, and estimated bone strength. METHODS: This investigation was a single center, parallel arm 12-month randomized controlled trial (RCT; NCT02822378) to evaluate the effects of 50 g and 100 g of prunes vs. a Control group on vBMD, bone geometry, and estimated strength of the radius and tibia via peripheral quantitative computed tomography (pQCT) in postmenopausal women. Women (age 62.1 ± 5.0yrs) were randomized into Control (n = 78), 50 g Prune (n = 79), or 100 g Prune (n = 78) groups. General linear mixed effects (LME) modeling was used to assess changes over time and percent change from baseline was compared between groups. RESULTS: The most notable effects were observed at the 14% diaphyseal tibia in the Pooled (50 g + 100 g) Prune group, in which group × time interactions were observed for cortical vBMD (p = 0.012) and estimated bone strength (SSI; p = 0.024); all of which decreased in the Control vs. no change in the Pooled Prune group from baseline to 12 months/post. CONCLUSION: Prune consumption for 12 months preserved cortical bone structure and estimated bone strength at the weight-bearing tibia in postmenopausal women.


Assuntos
Conservadores da Densidade Óssea , Pós-Menopausa , Feminino , Humanos , Pessoa de Meia-Idade , Idoso , Tíbia/diagnóstico por imagem , Densidade Óssea , Osso e Ossos , Conservadores da Densidade Óssea/uso terapêutico , Rádio (Anatomia)/diagnóstico por imagem , Absorciometria de Fóton
8.
Medicine (Baltimore) ; 103(5): e37146, 2024 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-38306529

RESUMO

RATIONALE: Radial nerve palsy in the newborn and congenital radial head dislocation (CRHD) are both rare disorders, and early diagnosis is challenging. We reported a case of an infant with concurrent presence of these 2 diseases and provide a comprehensive review of the relevant literature. The purpose of the study is to share diagnostic and treatment experiences and provide potentially valuable insights. PATIENT CONCERNS: A newborn has both radial nerve palsy and CRHD, characterized by limited wrist and fingers extension but normal flexion, normal shoulder and elbow movement on the affected side, characteristic skin lesions around the elbow, and an "audible click" at the radial head. The patient achieved significant improvement solely through physical therapy and observation. DIAGNOSES: The patient was diagnosed with radial nerve palsy in the newborn combined with CRHD. INTERVENTIONS: The patient received regular physical therapy including joint function training, low-frequency pulse electrical therapy, acupuncture, paraffin treatment, as well as overnight splint immobilization. OUTCOMES: The child could actively extend the wrist to a neutral position and extend all fingers. LESSONS: If a neonate exhibits limited extension in the wrist and fingers, but normal flexion, along with normal shoulder and elbow movement, and is accompanied by skin lesions around the elbow, there should be a high suspicion of radial nerve palsy in the newborn.


Assuntos
Articulação do Cotovelo , Luxações Articulares , Neuropatia Radial , Criança , Recém-Nascido , Humanos , Neuropatia Radial/diagnóstico , Neuropatia Radial/etiologia , Neuropatia Radial/terapia , Rádio (Anatomia)/diagnóstico por imagem , Cotovelo , Luxações Articulares/diagnóstico
9.
J Hand Surg Asian Pac Vol ; 29(1): 36-42, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38299239

RESUMO

Background: Despite the good clinical results in the treatment of Kienböck disease with distal radius core decompression, a radiological progression to a certain degree in the long-term follow-up is possible. Is there a negative correlation between the clinical improvement of the patients and the radiological progression? Methods: We retrospectively reviewed the radiological and clinical results of 24 patients (mean age: 38 years; 10 women) treated with core decompression for Kienböck disease. The mean follow-up was 10 years. Results: A radiologic progression in the Lichtman classification was seen in nine patients. The Spearman correlation did not show any correlation between this radiological progression and the clinical outcome. Namely -0.06 between Mayo and Lichtman classification and 0.16 between VAS and Lichtman classification. Conclusions: We found that the clinical outcomes do not deteriorate despite a radiological progression of patients treated with core decompression for Kienböck disease Level of Evidence: Level IV (Therapeutic).


Assuntos
Osteonecrose , Rádio (Anatomia) , Humanos , Feminino , Adulto , Rádio (Anatomia)/diagnóstico por imagem , Rádio (Anatomia)/cirurgia , Estudos Retrospectivos , Seguimentos , Osteotomia/métodos , Osteonecrose/diagnóstico por imagem , Osteonecrose/cirurgia , Descompressão
10.
Clin Orthop Surg ; 16(1): 113-124, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38304219

RESUMO

Background: Recently, deep learning techniques have been used in medical imaging studies. We present an algorithm that measures radiologic parameters of distal radius fractures using a deep learning technique and compares the predicted parameters with those measured by an orthopedic hand surgeon. Methods: We collected anteroposterior (AP) and lateral X-ray images of 634 wrists in 624 patients with distal radius fractures treated conservatively with a follow-up of at least 2 months. We allocated 507 AP and 507 lateral images to the training set (80% of the images were used to train the model, and 20% were utilized for validation) and 127 AP and 127 lateral images to the test set. The margins of the radius and ulna were annotated for ground truth, and the scaphoid in the lateral views was annotated in the box configuration to determine the volar side of the images. Radius segmentation was performed using attention U-Net, and the volar/dorsal side was identified using a detection and classification model based on RetinaNet. The proposed algorithm measures the radial inclination, dorsal or volar tilt, and radial height by index axes and points from the segmented radius and ulna. Results: The segmentation model for the radius exhibited an accuracy of 99.98% and a Dice similarity coefficient (DSC) of 98.07% for AP images, and an accuracy of 99.75% and a DSC of 94.84% for lateral images. The segmentation model for the ulna showed an accuracy of 99.84% and a DSC of 96.48%. Based on the comparison of the radial inclinations measured by the algorithm and the manual method, the Pearson correlation coefficient was 0.952, and the intraclass correlation coefficient was 0.975. For dorsal/volar tilt, the correlation coefficient was 0.940, and the intraclass correlation coefficient was 0.968. For radial height, it was 0.768 and 0.868, respectively. Conclusions: The deep learning-based algorithm demonstrated excellent segmentation of the distal radius and ulna in AP and lateral radiographs of the wrist with distal radius fractures and afforded automatic measurements of radiologic parameters.


Assuntos
Aprendizado Profundo , Fraturas do Rádio , Fraturas do Punho , Humanos , Fraturas do Rádio/cirurgia , Radiografia , Rádio (Anatomia)/diagnóstico por imagem , Placas Ósseas
11.
BMC Musculoskelet Disord ; 25(1): 20, 2024 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-38167040

RESUMO

BACKGROUND: Corticocancellous bone grafting from the iliac crest is acceptable treatment for unstable scaphoid nonunion with a viable proximal pole. However, harvesting graft from the iliac crest is associated with donor site morbidity and the requirement of general anesthesia. Thus, bone grafting from the anterolateral metaphysis of the distal radius (DR) can be a treatment option. However, no study has compared the clinical effect between the two grafting techniques. METHODS: From 2014 to 2019, patients with unstable scaphoid nonunion with humpback deformity underwent corticocancellous bone grafting from the anterolateral metaphysis of the DR (group DR) or iliac crest (group IC). Humpback deformity was determined by evaluating the scapholunate angle (SLA) ≥ 60°, intrascaphoid angle (ISA) ≥ 45°, and radiolunate angle (RLA) ≥ 15° from preoperative radiographs and computed tomography scans. The SLA, ISA, and RLA served to gauge carpal alignment. The operative time, grip strength, active range of motion (ROM), the Modified Mayo Wrist score (MMWS), and Disabilities of Arm, Shoulder, and Hand (DASH) score were assessed postoperatively. RESULTS: Thirty-eight patients qualified for the study (group DR, 15; group IC, 23). Union rates did not differ by patient subset (group DR, 100%; group IC, 95.7%; P = .827), and grip strength, ROM, MWS, and DASH score were similar between groups at the last follow-up. The operative time (minutes) was significantly shorter in group DR (median, 98; quartiles, 80, 114) than in group IC (median, 125; quartiles, 105, 150, P < .001). The ISA, RLA, and SLA improved postoperatively in both groups (P < 0.001). The degree of restoring carpal alignment, as evaluated by SLA, showed superior correction capability in group DR (median, 25.3% quartiles, 21.1, 35.3, P < 0.05). Donor site complications were not significantly different between the groups. CONCLUSIONS: Corticocancellous bone graft from the anterolateral metaphysis of the DR for unstable scaphoid nonunion is associated with a shorter operation time and comparable results with that from the iliac crest in regard to union, restoration of carpal alignment, and wrist function. LEVEL OF EVIDENCE: Level III.


Assuntos
Fraturas não Consolidadas , Osso Escafoide , Humanos , Rádio (Anatomia)/diagnóstico por imagem , Rádio (Anatomia)/cirurgia , Transplante Ósseo/métodos , Ílio/transplante , Fraturas não Consolidadas/diagnóstico por imagem , Fraturas não Consolidadas/cirurgia , Osso Escafoide/diagnóstico por imagem , Osso Escafoide/cirurgia , Fixação Interna de Fraturas/métodos , Estudos Retrospectivos
12.
Eur J Trauma Emerg Surg ; 50(1): 37-47, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38261077

RESUMO

PURPOSE: There is a debate whether corrective osteotomies of the distal radius should be performed using a 3D work-up with pre-contoured conventional implants (i.e., of-the-shelf) or patient-specific implants (i.e., custom-made). This study aims to assess the postoperative accuracy of 3D-assisted correction osteotomy of the distal radius using either implant. METHODS: Twenty corrective osteotomies of the distal radius were planned using 3D technologies and performed on Thiel embalmed human cadavers. Our workflow consisted of virtual surgical planning and 3D printed guides for osteotomy and repositioning. Subsequently, left radii were fixated with patient-specific implants, and right radii were fixated with pre-contoured conventional implants. The accuracy of the corrections was assessed through measurement of rotation, dorsal and radial angulation and translations with postoperative CT scans in comparison to their preoperative virtual plan. RESULTS: Twenty corrective osteotomies were executed according to their plan. The median differences between the preoperative plan and postoperative results were 2.6° (IQR: 1.6-3.9°) for rotation, 1.4° (IQR: 0.6-2.9°) for dorsal angulation, 4.7° (IQR: 2.9-5.7°) for radial angulation, and 2.4 mm (IQR: 1.3-2.9 mm) for translation of the distal radius, thus sufficient for application in clinical practice. There was no significant difference in accuracy of correction when comparing pre-contoured conventional implants with patient-specific implants. CONCLUSION: 3D-assisted corrective osteotomy of the distal radius with either pre-contoured conventional implants or patient-specific implants results in accurate corrections. The choice of implant type should not solely depend on accuracy of the correction, but also be based on other considerations like the availability of resources and the preoperative assessment of implant fitting.


Assuntos
Fraturas Mal-Unidas , Fraturas do Rádio , Cirurgia Assistida por Computador , Humanos , Rádio (Anatomia)/diagnóstico por imagem , Rádio (Anatomia)/cirurgia , Fraturas do Rádio/diagnóstico por imagem , Fraturas do Rádio/cirurgia , Cirurgia Assistida por Computador/métodos , Fraturas Mal-Unidas/cirurgia , Osteotomia/métodos
13.
Vet Surg ; 53(2): 234-242, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37309843

RESUMO

OBJECTIVE: To compare the accuracy of three-dimensional (3D) printed patient-specific guide (PSG) with a freehand (FH) approach for radial osteotomies in ex vivo normal dogs. STUDY DESIGN: Experimental study. ANIMALS: Twenty four ex vivo thoracic limb pairs from normal beagle dogs. METHODS: Computed tomography (CT) images were collected preoperatively and postoperatively. Three osteotomies tested (n = 8/group) were: (1) uniplanar 30° frontal plane wedge ostectomy, (2) oblique plane (30° frontal, 15° sagittal) wedge ostectomy, and (3) single oblique plane osteotomy (SOO, 30° frontal, 15° sagittal, and 30° external). Limb pairs were randomized to a 3D PSG or FH approach. The resultant osteotomies were compared with virtual target osteotomies by surface shape-matching postoperative to the preoperative radii. RESULTS: The mean ± standard deviation osteotomy angle deviation for all 3D PSG osteotomies (2.8 ± 2.8°, range 0.11-14.1°) was less than for the FH osteotomies (6.4 ± 6.0°, range 0.03-29.7°). No differences were found for osteotomy location in any group. In total, 84% of 3D PSG osteotomies were within 5° deviance from the target compared to 50% of freehand osteotomies. CONCLUSION: Three-dimensional PSG improved FH accuracy of osteotomy angle in select planes and the most complex osteotomy orientation in a normal ex vivo radial model. CLINICAL SIGNIFICANCE: Three-dimensional PSGs provided more consistent accuracy, which was most notable in complex radial osteotomies. Future work is needed to investigate guided osteotomies in dogs with antebrachial bone deformities.


Assuntos
Osteotomia , Rádio (Anatomia) , Humanos , Cães , Animais , Rádio (Anatomia)/diagnóstico por imagem , Rádio (Anatomia)/cirurgia , Osteotomia/veterinária , Osteotomia/métodos , Tomografia Computadorizada por Raios X/veterinária , Membro Anterior/cirurgia , Extremidade Superior , Imageamento Tridimensional
14.
Arch Orthop Trauma Surg ; 144(2): 975-984, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38063881

RESUMO

INTRODUCTION: The optimal treatment of chronic scapholunate instability has yet to be established. Scapholunate ligament grafts are still far from being the ideal solution. We conducted an experimental study to evaluate whether flexion-opening wedge osteotomy of the distal radius improves misalignment and avoids rotatory subluxation of the scaphoid in a cadaveric model of static scapholunate dissociative instability. MATERIALS AND METHODS: Radiographic studies were performed on 15 cryopreserved specimens after recreating a model of scapholunate instability by division of the scapholunate interosseous ligament (SLIL) and secondary stabilizers, taking radiographs at baseline, after the instability model, and after distal radius osteotomy. Static and dynamic (under controlled tendon traction) anteroposterior and lateral views were obtained to measure the length (in mm) of the carpal scaphoid and scapholunate interval, scapholunate angle, radio-lunate angle, and palmar tilt of the distal joint surface of the radius and to measure the dorsal scaphoid translation by the concentric circles method. The Wilcoxon test was used for statistical comparisons. RESULTS: The scapholunate interval was significantly decreased after osteotomy in all static anteroposterior views and in all lateral views under tendon traction. Dorsal scaphoid translation was significantly reduced in static lateral view in extension and in dynamic lateral view under 5-pound flexor carpi radialis tendon tension controlled by a digital dynamometer. CONCLUSIONS: Flexion-addition osteotomy of the distal radius appears to improve carpal alignment parameters in a cadaveric model of static scapholunate instability, achieving similar values to those obtained before instability.


Assuntos
Instabilidade Articular , Osso Semilunar , Osso Escafoide , Humanos , Rádio (Anatomia)/diagnóstico por imagem , Rádio (Anatomia)/cirurgia , Osso Semilunar/diagnóstico por imagem , Osso Semilunar/cirurgia , Osso Escafoide/diagnóstico por imagem , Osso Escafoide/cirurgia , Articulação do Punho/diagnóstico por imagem , Articulação do Punho/cirurgia , Instabilidade Articular/diagnóstico por imagem , Instabilidade Articular/cirurgia , Osteotomia , Cadáver , Ligamentos Articulares/diagnóstico por imagem , Ligamentos Articulares/cirurgia
15.
J Bone Miner Metab ; 42(1): 37-46, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38057601

RESUMO

INTRODUCTION: Forearm dual-energy X-ray absorptiometry (DXA) is often performed in clinics where central DXA is unavailable. Accurate bone mineral density (BMD) measurement is crucial for clinical assessment. Forearm rotation can affect BMD measurements, but this effect remains uncertain. Thus, we aimed to conduct a simulation study using CT images to clarify the effect of forearm rotation on BMD measurements. MATERIALS AND METHODS: Forearm CT images of 60 women were analyzed. BMD was measured at the total, ultra-distal (UD), mid-distal (MD), and distal 33% radius regions with the radius located at the neutral position using digitally reconstructed radiographs generated from CT images. Then, the rotation was altered from - 30° to 30° (supination set as positive) with a one-degree increment, and the percent BMD changes from the neutral position were quantified for all regions at each angle for each patient. RESULTS: The maximum mean BMD changes were 5.8%, 7.0%, 6.2%, and 7.2% for the total, UD, MD, and distal 33% radius regions, respectively. The analysis of the absolute values of the percent BMD changes from the neutral position showed that BMD changes of all patients remained within 2% when the rotation was between - 5° and 7° for the total region, between - 3° and 2° for the UD region, between - 4° and 3° for the MD region, and between - 3° and 1° for the distal 33% radius region. CONCLUSION: Subtle rotational changes affected the BMD measurement of each region. The results showed the importance of forearm positioning when measuring the distal radius BMD.


Assuntos
Antebraço , Rádio (Anatomia) , Humanos , Feminino , Antebraço/diagnóstico por imagem , Rádio (Anatomia)/diagnóstico por imagem , Densidade Óssea , Absorciometria de Fóton/métodos
16.
J Bone Joint Surg Am ; 106(4): 315-322, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-37995208

RESUMO

BACKGROUND: Three-dimensional (3D) preoperative planning is increasingly used in orthopaedic surgery. Two-dimensional (2D) characterization of distal radial deformities remains inaccurate, and 3D planning requires a reliable reference frame at the wrist. We aim to evaluate the reliability of the determination of anatomical points placed manually on 3D models of the radius to determine which of those points allow reliable morphometric measurements. METHODS: Twenty-three radial scans were reconstructed in 3D. Five operators specialized in the upper limb manually positioned 8 anatomical points on each model. One of the operators repeated the operation 6 times. The anatomical points were based on previously published 3D models used for radial inclination and dorsopalmar tilt measurements. The repeatability and reproducibility of the measurements derived using this manual landmarking were calculated using different measurement methods based on the identified points. An error of ≤2° was considered clinically acceptable. RESULTS: This study of intraobserver and interobserver variability of the anatomic points allowed us to determine the least variable and most accurately defined points. The middle of the ulnar border of the radius, the radial styloid, and the midpoint of the ulnar incisura of the radius were the least variable. The palmar and dorsal ends of the ridge delineating the scaphoid and lunate facets were the most variable. Only 1 of the radial inclination measurement methods was clinically acceptable; the others had a repeatability and reproducibility limit of >2°, making those measurements clinically unacceptable. CONCLUSIONS: The use of isolated points seems insufficient for the development of a wrist reference frame, especially for the purpose of measuring dorsopalmar tilt. If one concurs that an error of 2° is unacceptable for all distal radial measurements, then clinicians should avoid using 3D landmarked points, due to their unreliability, except for radial inclination measured using the radial styloid and the midpoint of the ulnar edge of the radius. A characterization of the wrist using 3D shapes that fit the articular surface of the radius should be considered. LEVEL OF EVIDENCE: Diagnostic Level III . See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Osso Semilunar , Fraturas do Rádio , Humanos , Punho , Reprodutibilidade dos Testes , Articulação do Punho/diagnóstico por imagem , Rádio (Anatomia)/diagnóstico por imagem , Fraturas do Rádio/cirurgia
17.
J Shoulder Elbow Surg ; 33(2): 373-380, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37879599

RESUMO

BACKGROUND: It has been suggested that hypertrophy of the radial tuberosity may result in impingement leading to either a lesion of the distal biceps tendon or rotational impairment. Two previous studies on hypertrophy of the radial tuberosity had contradictory results and did not examine the distance between the radius and ulna: the radioulnar window. Therefore, this comparative cohort study aimed to investigate the radioulnar window in healthy subjects and compare it with that in subjects with either nontraumatic-onset rotational impairment of the forearm or nontraumatic-onset distal biceps tendon ruptures with rotational impairment of the forearm by use of dynamic 3-dimensional computed tomography measurements to attain a comprehensive understanding of the underlying etiology of distal biceps tendon ruptures. We hypothesized that a smaller radioulnar window would increase the risk of having a nontraumatic-onset distal biceps tendon rupture and/or rotational impairment compared with healthy individuals. METHODS: This study measured the distance between the radius and ulna at the level of the radial tuberosity using entire-forearm computed tomography scans of 15 patients at the Amphia Hospital between 2019 and 2022. Measurements of healthy subjects were compared with those of subjects who had nontraumatic-onset rotational impairment of the forearm and subjects who had a nontraumatic-onset distal biceps tendon rupture with rotational impairment of the forearm. The Wilcoxon signed rank test was used for individual comparisons, and the Mann-Whitney U test was used for group comparisons. RESULTS: A significant difference was found between the radioulnar window in the forearms of the subjects with a distal biceps tendon rupture (mean, 1.6 mm; standard deviation 0.2 mm) and the radioulnar window in the forearms of the healthy subjects (mean, 4.8 mm; standard deviation, 1.4 mm; P = .018). A trend toward smaller radioulnar windows in the rotational impairment groups was also observed, although it was not significant (P > .05). CONCLUSIONS: The radioulnar window in the forearms of the subjects with a distal biceps tendon rupture with rotational impairment was significantly smaller than that in the forearms of the healthy subjects. Therefore, patients with a smaller radioulnar window have a higher risk of rupturing the distal biceps tendon. Nontraumatic-onset rotational impairment of the forearm may also be caused by a similar mechanism. Future studies are needed to further evaluate these findings.


Assuntos
Traumatismos do Braço , Traumatismos dos Tendões , Humanos , Rádio (Anatomia)/diagnóstico por imagem , Antebraço , Estudos de Coortes , Tendões , Traumatismos dos Tendões/diagnóstico por imagem , Traumatismos dos Tendões/etiologia , Traumatismos dos Tendões/cirurgia , Ruptura/diagnóstico por imagem , Ruptura Espontânea , Tomografia Computadorizada por Raios X
18.
J Hand Surg Eur Vol ; 49(3): 381-382, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37882687

RESUMO

We measured radiocarpal alignment in 150 standard lateral radiographs of normal wrists. In 84% of the cases, the lines of the long axis of the capitate and radius did not cross within the carpus.


Assuntos
Capitato , Ossos do Carpo , Humanos , Ossos do Carpo/diagnóstico por imagem , Articulação do Punho/diagnóstico por imagem , Punho , Capitato/diagnóstico por imagem , Rádio (Anatomia)/diagnóstico por imagem
19.
Clin Orthop Relat Res ; 482(3): 526-533, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37678226

RESUMO

BACKGROUND: Preoperative planning is generally performed to simulate the process of reduction as well as to determine the size and placement of implants in patients undergoing distal radius fracture surgery. We previously described a three-dimensional (3D) digital preoperative planning system for the osteosynthesis of distal radius fractures, and we have developed a novel intraoperative referencing system that superimposes preoperative planning (such as plate position and length) onto fluoroscopic images during surgery; however, its efficacy has not been evaluated compared with conventional planning and surgery. QUESTIONS/PURPOSES: Does use of a novel intraoperative referencing system result in (1) better Mayo wrist scores at 3 and 6 months after surgery and (2) less loss of reduction in terms of ulnar variance, palmar tilt, and radial inclination on plain radiographs taken 1 week, 3 months, and 6 months after surgery compared with conventional preoperative planning? METHODS: Between April 2014 and October 2021, we treated 294 patients with open reduction and volar plate fixation for distal radius fractures. Of 294 patients, 65% (191) underwent surgery using either conventional preoperative planning or a novel intraoperative referencing system. The remaining patients were excluded because they were younger than 18 years, they had some missing medical records related to the clinical outcomes, or they had a previous history of upper extremity injuries. During that time, we generally treated fractures with volar plates when there was: more than 2 mm of stepoff/gap in the articular surface, a dorsal tilt more than 15°, radial inclination less than 15°, or radial shortening more than 5 mm. Generally, we used a flexor carpi radialis approach. In some patients who had dorsal fragments, we added a dorsal approach. At that time, we were developing the new intraoperative referencing system, so it was not used consistently. To arrive at a fair assessment, we opted to perform propensity matching based on age, gender, and AO fracture type. During the period in question, 36% (69 of 191) of patients with distal radius fractures who received a volar plate were treated using our novel intraoperative referencing system, and 64% (122 of 191) had surgery using conventional preoperative planning (control group). Of those, 91% (63 of 69) of patients who were treated with the intraoperative referencing system and 89% (108 of 122) of those in the control group were available for follow-up with all imaging and Mayo wrist scores at least 6 months after surgery. After propensity matching, that left us with two groups of 39 patients, who were well matched in terms of age and fracture type; these were the study groups. We also tried to match them according to gender, but there were fewer patients in the intraoperative referencing group, and the percentage of women for each group differed: 70% (44 of 63) in the intraoperative referencing group and 76% (82 of 108) in the control group. Also, there were fewer men with C3 fractures in the control group. Therefore, 64% (25 of 39) of patients in the intraoperative referencing group were women and 77% (30 of 39) of patients in the control group were women. In the intraoperative referencing group, our novel intraoperative referencing system was used in combination with the 3D digital preoperative planning system for preoperative planning. In the control group, preoperative planning was performed manually in a conventional manner using tracing paper and implant templates or using a digital template. We compared the groups in terms of operative duration, the radiation dose used in surgery, and Mayo wrist scores at 3 and 6 months after surgery. We also compared the groups in terms of loss of reduction on ulnar variance, palmar tilt, and radial inclination on plain radiographs taken 3 months and 6 months after surgery. We considered the plain radiograph taken 1 week after surgery as a baseline. Each item was compared between the image fusion and control groups using a Welch t - test. RESULTS: Mayo wrist scores were no different between the intraoperative referencing system and the control group at 3 months (71 ± 7 versus 72 ± 11, mean difference 1 [95% CI -3.7 to 5.7]; p = 0.07) or at 6 months after surgery (76 ± 6 versus 79 ± 11, mean difference 3 [95% CI -3.5 to 7.9]; p = 0.12). There were no differences in surgical duration or radiation doses between the intraoperative referencing and control groups. We found only a small advantage in favor of the intraoperative referencing system in terms of loss of reduction on ulnar variance (3 months after surgery: 0.2 ± 0.4 mm versus 0.6 ± 0.7 mm, mean difference 0.4 mm [95% CI 0.15 to 0.69]; p = 0.003, 6 months after surgery: 0.4 ± 0.6 mm versus 0.8 ± 0.8 mm, mean difference 0.4 mm [95% CI 0.05 to 0.73]; p = 0.02 for the intraoperative referencing system and the control group, respectively). This difference in radial shortening was so small that it was not likely to have been clinically important. CONCLUSION: We found no clinically important advantages from the use of our novel intraoperative referencing system except a slight improvement in ulnar variance. Therefore, we recommend against its use in everyday practice at this time. However, future improvements may lead to better clinical outcomes, so we plan further investigations. LEVEL OF EVIDENCE: Level III, therapeutic study.


Assuntos
Fraturas do Rádio , Fraturas do Punho , Masculino , Humanos , Feminino , Fraturas do Rádio/diagnóstico por imagem , Fraturas do Rádio/cirurgia , Fraturas do Rádio/etiologia , Fluoroscopia , Radiografia , Rádio (Anatomia)/diagnóstico por imagem , Rádio (Anatomia)/cirurgia , Fixação Interna de Fraturas/efeitos adversos , Placas Ósseas , Amplitude de Movimento Articular , Resultado do Tratamento
20.
Endocrine ; 83(1): 205-213, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37597095

RESUMO

PURPOSE: Primary Hyperparathyroidism (PHPT) is associated with catabolic effects at both trabecular and cortical bone. Mechanical loading is one of the most important natural anabolic stimuli for bone at all ages. The present study was designed to assess the impact of PHPT on vBMD and bone geometry using peripheral quantitative computed tomography (pQCT) at the radius and tibia, sites with similar structural characteristics, but subject to different loading conditions. METHODS: We evaluated the impact of PHPT on bone, by comparing the z-scores of volumetric Bone Mineral Density (vBMD) and indices of bone geometry simultaneously at the tibia and the radius by pQCT, skeletal sites with similar structure, but subject to different loading conditions. Forty-one postmenopausal women with PHPT and 79 controls, comprised the study group. RESULTS: At both trabecular and cortical sites, vBMD and bone geometry indices were significantly lower in patients compared with controls. In patients with PHPT, apart from a lower z-score for total vBMD (p = 0.01) at the radius, there was no other difference between the radius and the tibia at the trabecular sites. On the contrary, at cortical sites, the z-scores of cortical bone mineral content (p = 0.02), cortical vBMD (p = 0.01) and cortical cross-sectional area (p = 0.05) were significantly lower at the radius compared with the tibia, indicating that cortical bone at the weight bearing tibia might be less affected by the catabolic actions of continuous parathyroid hormone (PTH) exposure. PTH levels were positively associated with the difference in z-scores of cort BMD (r = 0.439, p < 0.01) indicating that in more severe cases, as expressed by higher PTH levels, the deleterious effects at the non-weight bearing radius might be accentuated. CONCLUSION: We found that in postmenopausal women with PHPT, both trabecular and cortical bone are adversely affected. However, at the weight bearing tibia as compared with the radius, the deleterious effects, especially on cortical bone, seem to be attenuated. TRIAL REGISTRATION NUMBER: NCT05426512, 21/06/2022, "retrospectively registered".


Assuntos
Densidade Óssea , Hiperparatireoidismo Primário , Humanos , Feminino , Hiperparatireoidismo Primário/complicações , Hiperparatireoidismo Primário/diagnóstico por imagem , Pós-Menopausa , Osso e Ossos/diagnóstico por imagem , Hormônio Paratireóideo , Rádio (Anatomia)/diagnóstico por imagem , Absorciometria de Fóton
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...